3 phone software, 1 ftp/https access data, 3 phone software -81 – Siemens HIPATH 20 User Manual
Page 123: 1 ftp/https access data -81
administration.fm
A31003-O1010-M100-9-76A9, 05/05/2008
HiPath 8000 - OpenStage Family, Administration Manual
3-81
Administration
Transferring Phone Software, Application and Media Files
3.10.3
Phone Software
The firmware for the phone can be updated by downloading a new software file to the phone.
3.10.3.1
FTP/HTTPS Access Data
If the default FTP/HTTPS Access settings (see Section 3.10.2, “Common FTP/HTTPS Set-
tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec-
ified.
Data required (in every case)
•
Use default: Specifies whether the default FTP/HTTPS access settings shall be used. Val-
ue range: "Yes", "No".
Default: "No".
•
Filename: Specifies the file name of the phone software.
Data required (if not derived from Defaults)
•
Download method: Selects the protocol to be used.
Value range: "FTP", "HTTPS".
Default: "FTP".
•
Server address: IP address or hostname of the FTP/HTTPS server in use.
•
Server port: Port number of the FTP/HTTPS server in use.
Default: 21.
•
FTP account: Account at the server (if applicable).
•
FTP username: User name for accessing the server.
•
FTP password: Password corresponding to the user name.
•
FTP path: Path of the directory containing the files.
•
HTTPS base URL: IP address or hostname of the HTTPS server in use; only applicable if
Download method is switched to "HTTPS".
7
Do not disconnect the phone from the LAN or power unit during software update. An
active update process is indicated by blinking LEDs and/or in the display.