beautypg.com

Sanyo VSP-9000 User Manual

Page 90

background image

English

89

Others

Appendix

(Continued)

b

b

b

b

Special Code Chart

These functions can be loaded by entering their special codes.

ERNITEC SATURN............................................ 89

MARK MERCER ................................................ 90
PELCO .............................................................. 92

SENSORMATIC ................................................. 94

b

b

b

b

ERNITEC SATURN

Code

Function

AUTOPAN

301

Saves the current position of the first limit switch.

302

Saves the current position of the second limit switch.

XXX

XXX= 0 – 255: Auto-pan speed (0=min, 255=max)
Note: Cannot use with Saturn type.

PATROL

1000

Deletes patrol order.

1XXX

XXX= 1– 128: Writes preset position “XXX” into patrol order.

2000

2XXX

Makes patrol order valid.
X= 001 – 128: Deletes preset position “XXX” from patrol order.

3XXX

X= 000 – 255: Waiting time (in seconds) upon reaching specified position
Example:
“1000” Deletes previously defined order.
“1001” Writes preset position “1” into order.
“1005” Writes preset position “5” into order.
“1006” Writes preset position “6” into order.
“2005” Deletes preset position “5”.

OTHER FUNCTIONS

4XXY

Dome cameras can be set to automatically move to the "return position" after a
set stopping time passes.
XX= 01 – 99: “Return position” (Cannot select positions No. 100 to No. 128)
Y= 0 – 9: Return time
0: 10 seconds, 1: 20 seconds, 2: 30 seconds, 3: 40 seconds, 4: 1 minute,
5: 2 minutes, 6: 5 minutes, 7: 10 minutes, 8: 20 minutes, 9: 40 minutes

4000

Invalidates movement to “return position”.
Example:
4216”: After stopping for 5 minutes (Y=6), move to position 21 (XX=21).

400

Text display/non-display (switch)

500

Backlight compensation ON/OFF (switch)

9999

Initializes the dome camera internal memory.