beautypg.com

7 fan speed control, 8 environmental requirements, 1 physical environment – Intel OCPRF100 MP User Manual

Page 74: 2 thermal protection, 9 regulatory agency requirements, Fan speed control environmental requirements, Physical environment thermal protection, Regulatory agency requirements

background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

67

5.7

Fan Speed Control

The fan circuitry implements variable speed fan control and fan failure detection.

5.8

Environmental Requirements

5.8.1

Physical Environment

The power supply is located inside an Intel

®

system assembly. A system may contain two or

three power supplies.

5.8.2

Thermal Protection

The power supply incorporates thermal protection that causes a shutdown if air flow through the
power supply is insufficient. Thermal protection activates a shutdown if the temperature of any
power supply component is more than 85% (

°

C) of rated temperature. This shutdown takes place

prior to over-temperature induced damage to the power supply.

5.9

Regulatory Agency Requirements

The power supply must have UL recognition, CSA certification to level 3, Bauart and any NOR-
DIC CENELEC certified (such as SEMKO, NEMKO or SETI) markings demonstrating compli-
ance. The power supply must also meet FCC Class B, VDE 0871 Level B, and CISPR Class B
requirements.

Table 5-15: Power Supply LEDs and Output Signal State Logic

Power Supply LEDs

Power Supply Output Signal States

Input to
PS

Conditions

PWR
(green)

PRFL
(yellow)

FAIL
(yellow)

P_Good
H = pwr
good

Pred. Failure
H = pred.
failure

PS Failure
H = PS OK

PS On
H = PS
enable

No AC Power

OFF

OFF

OFF

L

L

L

L

AC In/Standby On

Blinking

OFF

OFF

L

L

H

L

DC Outputs OK

ON

OFF

OFF

H

L

H

H

Power Supply
Failure

OFF

OFF

ON

L

L

L

H

Current Limit

ON

OFF

Blinking/
No Latch

L

L

H

H

Predictive Failure

ON

Blinking/
Latched

OFF

H

H

H

H