63

† Measured relative to the power supply DC common output ground pins

5.6.3

Power Good (Output)

Each power supply provides a power good signal. A pin must be allocated for this signal. This
signal indicates that all outputs have reached acceptable operating voltage. The power good sig-
nal levels and sourcing/sinking requirements are shown in Table 5-10: Power Good Signal. The
power good signal is an output signal from the power supply to the system.

Measured relative to the power supply DC common output ground pins.

The power good signal is held low until all outputs have reached at least 90% of their respective
operating voltages. The turn on delay for the power good signal is between 100 and 1500 milli-
seconds.

The power good signal is low for a minimum of 1 millisecond before any of the output voltages fall
below the regulation limits. Tests are conducted with a maximum load and minimum line voltage.

Table 5-9: AC Good Signal

AC OK Signal

Voltage Level †

Current

LOW: AC is not yet up to the level.

0.4 V max

4 mA min sink current

HIGH: AC is up to the level.

4 V min

0.5 mA max source current

Table 5-10: Power Good Signal

Power Good Signal

Voltage Level †

Current

LOW STATE DE-ASSERTED
(Power Not Good)

0.4 V max

4 mA min sink current

HIGH STATE ASSERTED
(Power Good)

4 V min

0.5 mA max source current