2 baseboard management controller, Baseboard management controller – Intel OCPRF100 MP User Manual
Page 42
OCPRF100 MP Server System Technical Product Specification
Revision 1.0
35
the +5 V standby output of the power supply. The FPC takes part in implementing the following
system functions:
•
Power and reset switch interfaces
•
Fan failure detection
•
Chassis FRU inventory
•
System hard reset generation
•
System power fault indication
•
ICMB bridge device
•
Emergency management port (EMP)
•
LCD interface
3.4.2
Baseboard Management Controller
The baseboard management controller (BMC) on the OPRF100 board set I/O carrier provides
server management monitoring capabilities. Associated with the BMC is a flash memory that
holds the operation code and the BMC configuration defaults. The various server management
functions provided by the BMC are listed below.
•
Baseboard voltage monitoring
•
Processor voltage monitoring
•
Processor voltage ID (VID) monitoring
•
Processor presence detection
•
Processor internal error (IERR) and thermal trip monitoring
•
Fault resilient booting (FRB)
•
Processor disable control
•
Watchdog timer
•
Periodic system management interrupt (SMI) timer
•
I
2
C master controller
•
Private management bus interface
•
System management software (SMS) and SMM IPMB message receiver
•
Event message receiver
•
System event log management and access
•
Sensor data record (SDR) repository management and access
•
Processor NMI monitoring
•
Processor SMI monitoring
•
Time-stamp clock
•