beautypg.com

7 power supply kill (input), Power supply kill (input) – Intel OCPRF100 MP User Manual

Page 72

background image

OCPRF100 MP Server System Technical Product Specification

Revision 1.0

65

of that power supply is necessary. A “low” state indicates the power supply failure. The power
supply failure signal is an output signal from the power supply to the system.

† Measured relative to the power supply DC common output ground pins.

5.6.7

Power Supply Kill (Input)

The power supply kill signal is available on the power supply connector. The mating pin of this
signal on the backplane should be tied to ground potential on the backplane. Internal to the
power supply, the power supply kill pin should be connected to the +5 V standby through a pull-
up resistor.

Upon receiving a low state signal at the power supply kill pin, the power supply will be allowed to
turn on. A logic low on this pin by itself should not turn on the power outputs. With the power sup-
ply kill signal in a low state, a logic high signal on the power supply on signal will be able to turn
on the power supply.

When this pin is pulled up high (power supply is extracting from the backplane), the power supply
should be shut down immediately without any delay, regardless of the condition of the PS_On
signal.

The truth table for the logic of power supply kill and power supply on is shown in Table 5-13:
Logic Table for Power Supply Kill and Power Supply On.

The characteristics of the power supply kill signal are shown in Table 5-14: Power Supply Kill
Specification. The
power supply kill is an input signal to the power supply from the system.

Table 5-12: Power Supply Failure

Power Supply Failure Signal

Voltage Level †

LOW STATE (power supply failure)

0.4 V max

HIGH STATE (power supply OK)

4 V min

Table 5-13: Logic Table for Power Supply Kill and Power Supply On

Power Supply Kill

Power Supply On

Power Supply Conditions

Low

High

DC outputs are On

X

Low

DC outputs are Off

High

X

DC outputs are Off