Appendix C: Template File Reference

486

Netcool/Proviso Cisco IP Telephony Technology Pack User’s Guide, Version 4.3-W

Pack-Specific UBA Parameter Values

Additional Information on UBA Parameter Values

INSTANCES

The DataChannel UBA application supports multiple instances of technology packs running in a single channel
component. Therefore, there must be a way to guarantee that the UBA parses the correct design file and reads
the appropriate Bulk input files. The

INSTANCES

parameter helps ensure that the DataChannel UBA application

performs the correct operation for a specific technology pack.

The Cisco IP Telephony Technology Pack provides an

INSTANCES

parameter in its

voip_cisco_ipt_sample_dc.cfg

template file. You supply an arbitrary string — referred to as a group alias

— to the

INSTANCES

parameter. After you define the

INSTANCES

parameter with a specific string, make sure

you specify this string wherever appears in the template file.

You can associate this group alias with any arbitrary string. For example, you might associate this group alias with
the location (for example,

BOSTON

,

LOWELL

,

BERLIN

,

PARIS

, and so forth) of the data source.

URI

You must specify the Uniform Resource Identifier (URI) for each CCM Publisher bulk adaptor configured in the

dc.cfg

file.

The syntax for the URI is as follows. The variable portions of the URI string are indicated by italic text within
brackets (< >):

UBA.2.215.SANFRANCISCO.CCMINPUT.URI=sqldb:odbc*threaded/username=<userName>&

password=<password>&environment=<dataSourceName>

For example:

UBA.2.215.SANFRANCISCO.CCMINPUT.URI=sqldb:odbc*threaded/username=sa&password
=netcool&environment=SANFRANCISCO

Note:

The URIs you specify in the dc.cfg file must match the URIs of each CCM Publisher data source defined

in the odbc.ini file.

UBA Parameter Value

Meaning

Replace with the channel number that was configured for this
technology pack. This channel number appears in the dc.cfg
file.

Replace with the UBA Bulk Collector number that was configured
for this technology pack. This collector number appears in the
dc.cfg

file.

Replace the variable with an arbitrary string (for example,
LOWELL) that identifies a group alias to be associated with
subsequent lines in this section of the

dc.cfg

file. See Additional

Information on UBA Parameter Values on page 486 for more
information on this UBA parameter value.

Specify the URIs of each CCM Publisher data source defined in the

odbc.ini file.