Ds2100 user's manual (preliminary) – Moog DS2100 User Manual
Page 76

DS2100 User's Manual (Preliminary)
SECTION 3: WIRING AND INSTALLATION
PAGE 3-70
3.14.4 D Size Power Stage
-
Fixed connector: 4 pole, screw terminal
-
D size wiring: cable 6 AWG (13 mm
2
) for 50/140
-
D size wiring: cable 4 AWG ( 21mm
2
) for 60/180
-
PE Terminal wiring: cable 6 AWG (13 mm
2
) for 50/140
-
PE Terminal wiring: cable 4 AWG (21 mm
2
) for 60/180
-
Stripping Length 16mm
-
Tightening Torque: 2-2.3Nm
Pos.
Name
Function
J9.1
RR
Regeneration Resistance
J9.2
DC+(RR)
DC Bus (+)
J9.3
PE
Protective Earth Screw Terminal
J9.4
L1
Phase "L1", three-phase voltage input 230/460Vac
±10%
J9.5
L2
Phase "L2", ", three-phase voltage input 230/460Vac
±10%
J9.6
L3
Phase "L3", ", three-phase voltage input 230/460Vac
±10%
J9.7
U
Motor Phase U
J9.8
V
Motor Phase V
J9.9
W
Motor Phase W
J9.10
PE
Motor Protective Earth
J9.11
DC+
DC Bus (+)
J9.12
DC-
DC Bus (-)
-
Fixed connector: 2 pins, male connector
-
Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
-
D size wiring: cable 14 AWG (2.1 mm
2
).
-
Stripping Length 8mm
Pos.
Name
Function
J8.1
24V
+24V Logic Backup Supply
J8.2
0V
Logic Supply Return