Ds2100 user's manual (preliminary), 2 size a,b,c & d 24v input connection – Moog DS2100 User Manual
Page 39
![background image](/manuals/121907/39/background.png)
SECTION 3: WIRING AND INSTALLATION
DS2100 User's Manual (Preliminary)
PAGE 3-33
3.8.2 Size A,B,C & D 24V Input Connection
1 2
Connector J8
A,B,C & D
24V Auxiliary
Supply
+24V
GND (0V)
Schaffner
FN2070-3-06
Filter
Fuse
Figure 3.20 Size A,B, C & D 24V DC Input Connection
-
Fixed connector: 2 pins, male connector
-
Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)
-
A,B,C & D size wiring: cable 14 AWG (2.1 mm
2
).
-
Stripping Length 8mm
Pos.
Name
Function
J8.1
24V
+24V Logic Backup Supply
J8.2
0V
Logic Supply Return
Table 3.8 J8 24V Logic Power connector, A,B,C & D Size