24v backup connection, Ds2100 user's manual (preliminary), 8 24v backup connection – Moog DS2100 User Manual
Page 38
![background image](/manuals/121907/38/background.png)
DS2100 User's Manual (Preliminary)
SECTION 3: WIRING AND INSTALLATION
PAGE 3-32
3.8 24V Backup Connection
The DS2100 is equipped with a 24V logic supply backup. This backup supply provides logic power to the drive when
AC mains power is removed.
For the
mA size, this backup is mandatory for drive operation.
3.8.1 Size
mA 24V Input Connection
11 12
11 12
Connector J6
mDS
24V Auxiliary
Supply
+24V
GND (0V)
Connector J6
mDS
Fairrite Clamp Core
p/n # 00443164151
(4-Turns of Supply
cable)
Fuse
Figure 3.19 Size
mA 24V DC Input Connection
-
Fixed connector: 12 pins, male connector
-
Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)
-
mA size wiring: cable 14 AWG (2.1 mm
2
).
-
Stripping Length 7mm
-
Tightening torque: 0.5Nm.
Pos.
Name
Function
J6.11
24V
+24V Logic Backup Supply
J6.12
0V
Logic Supply Return (Tied Internally to PE )
Table 3.7 J6 24V Logic Power connector,
mA Size