beautypg.com

Ds2100 user's manual (preliminary) – Moog DS2100 User Manual

Page 57

background image

SECTION 3: WIRING AND INSTALLATION

DS2100 User's Manual (Preliminary)

PAGE 3-51

3.11.4 Motor Resolver Connection

Wire the DS2100 resolver cable in accordance with Figure 3.37 and Table 3.24.

For CE compliance, shield should be attached on both sides of resolver
cable.

Required for

CE-Compliance

NOTE:- Avoid running the resolver cable near other high
power wiring, especially the motor power cable, if possible.

NOTE:- Cable Length should not exceed 30m (100 feet).