3.11.2.4 Size
D
PE
PE (J9.4)
Motor
U (J9.1)
V (J9.2)
grounding of shield
via connector clamp
W (J9.3)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J9
DS2100 D
Figure 3.32 DS2100 D Motor Power Connection
J9
-
Fixed connector: 4 pole, screw terminal
-
D size wiring: cable 6 AWG (13 mm
2
) for 50/140
-
D size wiring: cable 4 AWG ( 21mm
2
) for 60/180
-
Stripping Length 16mm
-
Tightening Torque: 2-2.3Nm
Pos.
Name
Function
J9.10
PE
Motor Protective Earth
J9.9
W
Motor Phase W
J9.8
V
Motor Phase V
J9.7
U
Motor Phase U
Table 3.21 J9, Motor connector, D Size