SECTION 3: WIRING AND INSTALLATION
PAGE 3-44
3.11.2.1 Size
mA
PE
PE (J6.7)
Motor
U (J6.10)
V (J6.9)
grounding of shield
via connector clamp
W (J6.8)
V
W
U
grounding of shield
via connector clamp
(or RF connection to
ground screw in
case of terminal board)
J6
DS2100 mA
Figure 3.29 DS2100
mA Motor Power Connection
-
Fixed connector: 12 pins, male connector
-
Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)
-
mA size wiring: cable 14 AWG (2.1 mm
2
). Wire stripping: 7 mm.
-
Tightening torque: 0.5Nm.
Pos.
Name
Function
J6.7
PE
Motor Protective Earth
J6.8
W
Motor Phase W
J6.9
V
Motor Phase V
J6.10
U
Motor Phase U
Table 3.18 J6, Motor connector,
mA Size