beautypg.com

Motorola PTP 400 Series User Manual

Page 150

background image

148

The PTP 400 Series Bridge PIDU Plus to ODU cable requires Surge Arrestor Units mounted

at both ends of the cable. At the ODU, the Surge Arrestor Unit should be mounted within

0.3m (1 foot) of the ODU and must be grounded to the ODU. For mast installations, the Surge

Arrestor Unit should be mounted at the same height as the ODU.

The lower Surge Arrestor Unit should be mounted at the building entry point and must be

grounded.

The termination of the CAT-5 Cable into the Surge Arrestor Unit is illustrated in Table 16,

Table 17 and Figure 81. The screen from the cable must be terminated into the ground

terminal within the unit to ensure the continuity of the screen. Earth Sleeving should be used

to cover the shield ground connection to prevent internal shorting within the unit.

Terminal Identification

Conductor

RJ45 Pin

CON3 Pin 1

Orange/White

1

CON3 Pin 2

Orange

2

CON3 Pin 3

Green/White

3

CON3 Pin 6

Green

6

CON1 Pin 4

Blue

4

CON1 Pin 5

Blue/White

5

CON1 Pin 7

Brown/White

7

CON1 Pin 8

Brown

8

Table 16 - Surge Arrestor ALPU-ORT Cable 1 Termination