The user should ensure that the correct image is shown before pressing the “Program

Software Image into Non-Volatile Memory” button. Once this button has been pressed the

image is stored into non-volatile memory. This process can take up to 60 seconds and must

not be interrupted. A progress tracking web page will be presented to the user during the

erasure and programming of non-volatile memory.

WARNING: If the upgrade process is interrupted during the erasure of the image bank or

during the reprogramming of the image bank the image bank will be left in a corrupt state. If

this occurs the software must be reloaded. On power up, if the software image is invalid, for

any reason, the PTP 400 Series bridge will use a known good fixed image. If this occurs the

user must attempt to reload the correct version of software.

Figure 54 - Overall Progress Tracker