beautypg.com

6 barring channels, Barring channels – Motorola PTP 400 Series User Manual

Page 119

background image

117

Hopping Margin:

Spectrum Management uses this margin when making a channel hop

decision. The channel to hop to has to have an interference level 3 dBs (default) better than

the current active channel. Hopping Counter is used to record the number of channel hops.

The number in the “(+ )” brackets indicates the number of channel changes since the last

screen refresh.

Hopping Counter:

Indicates the number of automatic channel changes that have occurred.

Asymmetric DFS:

When disabled this option constrains the link to operate symmetrically

using the same transmit and receive channels. When in symmetric mode the slave unit will

always follow the master. If the master moves to a new channel the slave will hop to the same

channel. When the Point-to-Point link is configured as an asymmetric link both the master and

slave are free to select the best channel from their own set of local interference metrics.

(Default Enabled).

Interference Threshold:

Spectrum Management uses the interference threshold to perform

instantaneous channel hops. If the measured interference on a channel exceeds the specified

threshold then Spectrum Management will instruct the wireless to immediately search for a

better channel. If a better channel cannot be found, the PTP 400 Series Bridge will continue

to use the current active channel. (Default –85 dBm)

8.3.8.6 Barring

Channels

Channels can only be barred / unbarred by the system administrator from the master

Spectrum Management web page. The barring / unbarring operations are disabled on the

slave web page. If an attempt to bar / unbar a channel is made at the slave a warning dialog

is generated.

Barring / Unbarring of channels is performed by clicking the appropriate channel on the local

or peer channel spectrum plots on the master web page. Each bar / unbar attempt will be

proceeded by a conformation dialog. It should be noted that the channel bar will take effect

immediately and is not related to the measurement quantization period.