Technical Configuration

MultiVOIP FX User Guide

84

FXO Interface: Parameter Definitions*

FXO Options

Ring Count

1-99

Number of rings required
before the MultiVOIP answers
the incoming call.

No Response
Timer

1 – 65535
(in seconds)

Length of time before call
connection attempt is
abandoned.

Flash
Generation

50 - 1500
milliseconds

Length of flash hook that will
be generated and sent out when
the remote end initiates a flash
hook and it is regenerated
locally. Default = 600 ms.

Disconnect Options

Current Loss

Y/N

Disconnection to be triggered
by loss of current. That is,
when Current Loss is enabled
(“Y”), the MultiVOIP will hang
up the call at a specified
interval after it detects a loss of
current initiated by the attached
device.

Current Loss
Timer

200 to 2000
(in milliseconds)

Determines the interval after
detection of current loss at
which the call will be
disconnected.

DTMF Tone

Y/N

Enables supervision of call
disconnection using DTMF
tones.

Low Tones

697Hz

770Hz

852Hz

941Hz

High Tones 1209Hz 1336Hz 1447Hz 1633Hz

DTMF Tone Pairs

1

4

7

*

2

5

8

0

3

6

9

#

A

B

C

D