Environmental, Synthesiser – Maxon Telecom SP210 User Manual
Page 12

Maxon SP200/210 Radio SP200/210
SPECIFICATIONS DRAFT Issue 1.0
Page 2-2
03/01
Environmental
Operating Temperature Range
-15 to +35°C (nominal)
-20 to +55°C (extreme),
Storage Temperature Range
-40 to +80°C (storage)
Charging Temperature Range
0 to +30°C
Humidity
EIA/TIA 603 (95%)
Protection against ingress of
IEC 529 IP54
dust and water
Vibration
BS2011 : Part 2.1Fc IEC 68-2-6
Part 2.1Fd IEC 68-2-34
Robustness
Mil Std 810 C Procedures I, II & V
ESD
20kV (C-MIC >= 15kV)
EMC
EMC Directive 89/336/EEC May 89
Physical Dimensions
112 x 61 x 40mm
(Excluding antenna and with QPA1350 pack)
Synthesiser
Reference Crystal
Frequency: 12.8MHz
Holder: HC-18
Accuracy:
±
3ppm over –30 to +60
°
C
Ageing Rate:
< 2ppm / Year in the first year
< 1ppm / Year in subsequent years
Synthesiser Lock Time:
< 10mS
Switching Times
Tx to Rx, same frequency
< 20mS
Rx to Tx, same frequency
< 20mS
Rx to Rx
< 20mS
(over switching bandwidth)
Rx to Tx / Tx to Rx
< 20mS
(over switching bandwidth)
Receiver Sensitivity
<-118dBm (VHF), <-117dBm (UHF)
Squelch Sensitivity
7 – 12dB SINAD
Adjacent Channel Selectivity
Better than 70dB
Sub Audio Tones – CTCSS / DCS
Decode Sensitivity Method (decrease signal level @ 10% peak deviation)
All tones
<=9dB SINAD
CTCSS Tone Range
67 – 250Hz @ 0.3% accuracy
50 – 260Hz @ 0.3% accuracy (non-standard tones)
DCS Tone Standard
Standard & Inverted
Programmer
SMP 6100