SCSI Description
5-22
Maxtor Atlas 10K III
Note:
Vendor Information, Product Identification, and Product Revi-
sion Level are returned as shown in Table 5-22.
ACKQREQQ
0
Device supports REQ and ACK data handshake on Q cable.
Addr32
0
32-bit wide SCSI address
Addr16
0/1
16-bit wide SCSI address
TrmTSK
0
TERMINATE TASK Function is not supported
Response Data For-
mat
2
This Standard Inquiry Data is in the format specified in the International
Standard.
RelAdr
0
Relative Addressing is not supported.
WBus 32
0
32-bit wide bus is not supported.
WBus 16
0 or 1
The WBus bit is 1 if the drive supports 16-bit data transfer. The bit is 0
if the drive only supports 8-bit transfer.
Sync
1
The drive supports Synchronous Data Transfers.
Linked
1
Linked Commands are supported.
TransDis 1
Indicates that the drive supports CONTINUE TASK and TARGET
TRANSFER DISABLE messages.
CmdQue
1
The drive supports Tagged Command Queuing
SftRe 0
The drive implements the hard reset option in response to assertion of
the SCSI Bus reset line.
VS
0
Vendor Specific
Product
Identification
The
value in
this field
is:
ATLAS10K3_18_WLS, ATLAS10K3_36_WLS, ATLAS10K3_73_WLS
ATLAS10K3_18_SCA, ATLAS10K3_36_SCA, ATLAS10K3_73_SCA
Clocking 11
The contents of this field define the setting of the double-edge clocking
option (See Chapter 6). Note that the clocking field does not apply to
asynchronous transfers of data. Options available are:
%QFG
00b
01b
10b
11b
&GUETKRVKQP
Indicates the device server supports only Single
Transition (ST)
Indicsates the device server supports only Double
Transition (DT)
Reserved
Indicates the device server supports ST and DT
QAS
0
(U160)
Quick Arbritrate Support. If the value of this field is 1, it indicates that
the device server supports the quick arbitrate feature. A value of 0 in-
dicates that the device server does not support this feature. 0 is default
setting.
IUS
1
(U320)
Information Unit Supported. If the value of this field is 1, it indicates
that the device server supports information units. A value of 0 indicates
that the device server does not support information units. Default is 0.
(KGNF 0COG
8CNWG
&GUETKRVKQP