Maxtor ATLAS 10K III User Manual
Maxtor Hardware
Table of contents
Document Outline
- 1.1 AUDIENCE
- 1.2 MANUAL ORGANIZATION
- 1.3 TERMINOLOGY AND CONVENTIONS
- 1.4 REFERENCES
- 2.1 PRODUCT OVERVIEW
- 2.2 KEY FEATURES
- 2.3 Regulatory Compliance Standards
- 2.4 HARDWARE REQUIREMENTS
- 3.1 SAFETY, HANDLING, & ELECTROSTATIC DISCHARGE PROTECTION
- 3.2 SPACE REQUIREMENTS
- 3.3 UNPACKING INSTRUCTIONS
- 3.4 HARDWARE OPTIONS
- 3.5 INTERFACE CONNECTOR (J1)
- 3.6 4-pin DC Power Connector (68-Pin Connector)
- 3.7 4-pin Mating Connector
- 3.8 J1 12-pin Auxiliary Connector (68-pin Connector)
- 3.9 DRIVE MOUNTING and installation
- 4.1 SPECIFICATION SUMMARY
- 4.2 FORMATTED CAPACITY
- 4.3 DATA TRANSFER RATES
- 4.4 TIMING SPECIFICATIONS
- 4.5 POWER
- 4.6 ACOUSTICS
- 4.7 MECHANICAL
- 4.8 ENVIRONMENTAL CONDITIONS
- 4.9 ELECTROMAGNETIC CONDITIONS
- 4.10 SHOCK AND VIBRATION
- 4.11 RELIABILITY
- 4.12 DISK ERRORS
- 5.1 Overview of the SCSI Command Descriptions
- 5.2 Command Descriptor Block
- 5.3 Status/Error Reporting
- 5.4 Auto Contingent Allegiance Condition and Contingent Allegiance Condition
- 5.5 Extended Contingent Allegiance Condition
- 5.6 Linked Commands
- 5.7 DATA Transfer Command Components
- 5.8 SCSI COMMAND DESCRIPTIONS
- 5.9 CHANGE DEFINITION Command (40h)
- 5.10 FORMAT UNIT Command (04h)
- Table 5-11 FORMAT UNIT Command Descriptor Block-Data Format
- Table 5-12 FORMAT UNIT Command-Field Descriptions
- 5.10.1 Five Forms of FORMAT UNIT Command s
- 5.10.2 FORMAT UNIT Parameter List
- Table 5-14 FORMAT UNIT Parameter List-Data Format
- Table 5-15 .FORMAT UNIT Defect List Header-Data Format
- Table 5-16 FORMAT UNIT Defect List Header-Field Descriptions
- Table 5-17 FORMAT UNIT Defect Descriptor-Block Format
- Table 5-18 FORMAT UNIT Defect Descriptor- Physical Sector and Bytes From Index Format
- Table 5-19 FORMAT UNIT Initialization Pattern Descriptor-Data Format
- Table 5-20 FORMAT UNIT Initialization Pattern Descriptor-Field Descriptions
- Table 5-21 FORMAT UNIT Initialization Pattern Type
- 5.11 INQUIRY Command (12h)
- Table 5-22 INQUIRY Command Descriptor Block-Data Format
- Table 5-23 INQUIRY Command Descriptor Block-Field Descriptions
- 5.11.1 Standard Inquiry Data Page
- 5.11.2 Vital Product Data Pages
- Table 5-26 Supported Vital Product Data Pages -Data Format
- Table 5-27 Vital Product Data-Page Codes
- Table 5-28 Unit Serial Number Page-Data Format
- Table 5-29 Unit Serial Number Page-Field Descriptions
- Table 5-30 Implemented Operating Definition Page-Data Format
- Table 5-31 Implemented Operating Definition Page-Field Descriptions
- Table 5-32 ASCII Implemented Operating Definition Page - Data Format
- Table 5-33 Device Identification Page - Data Format
- Table 5-34 Device Identification Page-Field Description
- Table 5-35 Firmware Revision Page -Data Format
- Table 5-36 Maxtor Manufacturing Information Page-Data Format
- Table 5-37 Negotiated Rate Information Page-Data Format
- Table 5-38 Negotiated Rate Information Page-Field Descriptions
- Table 5-39 Command Support Data Page-Data Format
- Table 5-40 Command Support Data Page-Field Descriptions
- Table 5-41 Command Support Data Page Command or Operation Codes
- 5.12 LOG SELECT Command (4Ch)
- 5.13 LOG SENSE Command (4Dh)
- 5.14 MODE SELECT (6) Command (15h)
- Table 5-51 MODE SELECT (6) Command Descriptor Block-Data Format
- Table 5-52 MODE SELECT (6) Command Field Descriptions
- 5.14.1 Initiator-Changeable Mode Pages
- 5.14.2 Mode Page Types
- 5.14.3 Mode Parameter List
- Table 5-55 Mode Parameter List-Data Format
- Table 5-56 Mode Parameter List-Field Descriptions
- Table 5-57 Mode Parameter Header (6-Byte)-Data Format
- Table 5-58 Mode Parameter Header- Field Descriptions
- Table 5-59 Mode Parameter Block Descriptor-Data Format
- Table 5-60 Mode Parameter Block Descriptor-Field Descriptions
- Table 5-61 Categories of Changeable Pages
- Table 5-62 Unit Attention Condition Page (Page 0)
- Table 5-63 Unit Attention Condition Page (Page 0)
- Table 5-64 Read-Write Error Recovery Page-(Page 1)
- Table 5-65 Read-Write Error Recovery Page-(Page 1)
- Table 5-66 Disconnect–Reconnect Page (Page 2)
- Table 5-67 Disconnect-Reconnect-Field Descriptions (Page 2)
- Table 5-68 Verify Error Recovery Page-(Page 7)
- Table 5-69 Verify Error Recovery Page-Field Descriptions (Page 7)
- Table 5-70 Caching Page-(Page 8)
- Table 5-71 Caching Page-(Page 8)
- Table 5-72 Control Mode Page-(Page 0Ah)
- Table 5-73 Control Mode Page-Field Descriptions (Page 0Ah)
- Table 5-74 Notch and Partition Page-(Page 0Ch)
- Table 5-75 Notch and Partition Page-Field Descriptions (Page 0Ch)
- Table 5-76 Port Control Page Short Format
- Table 5-77 Port Control Page Long Format
- Table 5-78 Power Condition Page-(Page 1Ah)
- Table 5-79 Power Condition Page-Field Descriptions (Page 1Ah)
- Table 5-80 Information Exceptions Control Page-(Page 1Ch)
- Table 5-81 Information Exceptions Control Page-Field Descriptions (Page 1Ch)
- Table 5-82 Codes Used by the MRIE Field
- Table 5-83 Maxtor-Unique Page-Data Format (Page 39h)
- Table 5-84 Maxtor-Unique Page-Field Descriptions (Page 39h)
- 5.15 MODE SELECT (10) Command (55h)
- 5.16 MODE SENSE (6) Command (1Ah)
- Table 5-89 MODE SENSE (6) Command Descriptor Block-Data Format
- Table 5-90 MODE SENSE Command-Field Descriptions
- Table 5-91 Mode Parameter Header (6 Byte)-Data Format
- Table 5-92 Mode Parameter Header-Field Descriptions
- 5.16.1 Read-Only Mode Pages
- 5.16.2 Format Device Page (03h)
- 5.16.3 Rigid Disk Geometry Page (04h)
- 5.16.4 Margin Control Subpage
- 5.16.5 Saved Training Configuration Values Subpage
- 5.16.6 Negotiated Settings Subpage
- 5.16.7 Maxtor-Unique Caching Page (38h)
- 5.17 MODE SENSE (10) Command (5Ah)
- 5.18 PERSISTENT RESERVATION IN Command (5Eh)
- Table 5-108 PERSISTENT RESERVATION IN Command Descriptor Block-Data Format
- Table 5-109 PERSISTENT RESERVATION IN Command-Field Descriptions
- Table 5-110 Read Keys Parameters-Data Format
- Table 5-111 Read Keys Parameters-Field Descriptions
- Table 5-112 Read Reservations Parameters-Data Format
- Table 5-113 Read Reservations Parameters-Field Descriptions
- Table 5-114 PERSISTENT RESERVATION IN Read Reservations Descriptor-Data Format
- Table 5-115 PERSISTENT RESERVATION IN Read Reservations Descriptor-Field Descriptions
- Table 5-116 Persistent Reservation Type Codes and Their Meanings
- Table 5-117 When Do Conflicts Between Existing Reservations and New Reservations Exist?
- 5.19 PERSISTENT RESERVATION OUT Command (5Fh)
- Table 5-118 PERSISTENT RESERVATION OUT Command Descriptor Block-Data Format
- Table 5-119 PERSISTENT RESERVATION OUT Command-Field Descriptions
- Table 5-120 PERSISTENT RESERVATION OUT Command’s Service Action Descriptions
- Table 5-121 Persistent Reservation Type Codes and Their Meanings
- Table 5-122 .PERSISTENT RESERVATION OUT Parameter List-Data Format
- Table 5-123 PERSISTENT RESERVATION OUT Parameter List-Field Descriptions
- Table 5-124 Device Server Interpretation of Service and Scope Value
- 5.20 READ (6) Command (08h)
- 5.21 READ (10) Command (28h)
- 5.22 READ BUFFER Command (3Ch)
- 5.23 READ CAPACITY Command (25h)
- 5.24 READ DEFECT DATA Command (10) (37h)
- Table 5-134 READ DEFECT DATA (10) Command -Data Format
- Table 5-135 READ DEFECT DATA (10) Command -Field DescriptionREAD DEFECT
- Table 5-136 Defect Descriptor-Block Format.
- Table 5-137 Defect Descriptor-Bytes From Index Format, or Physical Sector Format
- Table 5-138 Defect List Header -Data Format
- Table 5-139 Defect List Header -Field Descriptions
- 5.25 READ DEFECT DATA Command (12) (B7h)
- Table 5-140 READ DEFECT DATA (12) Command -Data Format
- Table 5-141 READ DEFECT DATA (12) Command-Field Description
- Table 5-142 Defect Descriptor-Block Format
- Table 5-143 Defect Descriptor-Bytes From Index Format, or Physical Sector Format
- Table 5-144 Defect List Header-Data Format
- Table 5-145 Defect List Header -Field Descriptions
- 5.26 READ LONG Command (3Eh)
- 5.27 READ SKIP MASK Command (E8h)
- 5.28 REASSIGN BLOCKS Command (07h)
- 5.29 RECEIVE DIAGNOSTIC RESULTS Command (1Ch)
- 5.30 RELEASE (6) Command (17h)
- 5.31 RELEASE (10) Command (57h)
- 5.32 REPORT DEVICE IDENTIFIER Command (A3h)
- 5.33 REPORT LUNS Command (A0h)
- 5.34 REQUEST SENSE Command (03h)
- Table 5-172 REQUEST SENSE Command Descriptor Block-Data Format
- Table 5-173 REQUEST SENSE Command Descriptor Block-Field Description
- 5.34.1 Sense Data Availability
- 5.34.2 Status Reporting
- 5.34.3 Sense Data Format for Error Code 70h and Error Code 71h
- Table 5-174 Sense Data Format for Error Code 70h or 71h-Data Format
- Table 5-175 Sense Data Fields (Error Code 70h)-Field Descriptions
- Table 5-176 Supported Sense Key s
- Table 5-177 Sense Key Information Field Contents
- Table 5-178 Supported Additional Sense Codes and Sense Code Qualifiers (in Hex)
- Table 5-179 Sense-Key Specific Field Contents
- Table 5-180 ILLEGAL REQUEST Sense Key Field Pointer Bytes\Data Format
- Table 5-181 ILLEGAL REQUEST Sense Key Field Pointer Bytes \Field Descriptions
- Table 5-182 NOT READY Sense Key - Progress Indication Bytes\Data Format
- Table 5-183 NOT READY Sense Key - Progress Indication Bytes\Field Descriptions
- Table 5-184 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count-Data Format
- Table 5-185 Table 5–90 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count
- 5.35 RESERVE (6) Command (16h)
- 5.36 RESERVE (10) Command (56h)
- Table 5-188 RESERVE (10) Command Descriptor Block-Data Format
- Table 5-189 RESERVE (10) Command -Field Descriptions
- Table 5-190 Extent Descriptors-Data Format
- Table 5-191 Reservation Types
- Table 5-192 Parameter List When LongID and Extent Bits = 1-Data Format
- Table 5-193 RESERVE (10) ID Only Parameter List-Data Format
- 5.37 REZERO UNIT Command (01h)
- 5.38 SEEK (6) Command (0Bh)
- 5.39 SEEK (10) Command (2Bh)
- 5.40 SEND DIAGNOSTIC Command (1Dh)
- 5.41 SET DEVICE IDENTIFIER Command (A4h)
- 5.42 START STOP UNIT Command (1Bh)
- 5.43 SYNCHRONIZE CACHE Command (35h)
- 5.44 TEST UNIT READY Command (00h)
- 5.45 VERIFY Command (2Fh)
- 5.46 WRITE (6) Command (0Ah)
- 5.47 WRITE (10) Command (2Ah)
- 5.48 WRITE AND VERIFY Command (2Eh)
- 5.49 WRITE BUFFER Command (3Bh)
- 5.50 WRITE LONG Command (3Fh)
- 5.51 WRITE SAME Command (41h)
- 5.52 WRITE SKIP MASK Command (EAh)
- 6.1 KEY FEATURES
- 6.2 PREFETCH
- 6.3 WRITE-BACK CACHING
- 6.4 ZERO LATENCY READ/WRITE
- 6.5 DISCONNECT-RECONNECT
- 6.6 TRACK AND CYLINDER SKEWING
- 6.7 AVERAGE ACCESS TIME
- 6.8 EMBEDDED SERVO SYSTEM
- 6.9 DATA INTEGRITY AND SECURITY
- 6.10 TAGGED COMMAND QUEUING
- 6.11 COMMAND REORDERING
- 6.12 BANDED RECORDING
- 6.13 SPECIAL FUNCTIONS
- 6.14 POWER MANAGEMENT
- 6.15 DIAGNOSTICS
- 6.16 ERROR RECOVERY
- 6.17 SCSI CONFIGURED AUTOMATICALLY (SCAM)
- 6.18 THE ULTRA160 and ULTRA320 LOW VOLTAGE DIFFERENTIAL (LVD) SCSI INTERFACE
- 6.19 HOT PLUGGING/REMOVAL AND INSERTION OF SCSI DEVICES
- A.1 SCSI-2/SCSI-3 Equivalent Terminology
- A.2 SCSI Commands and Messages
- A.3 SCSI Pages
- A.4 Sense Keys
- A.5 Status Codes
- B.1 TRANSFER PERIOD FACTOR FIELD
- B.2 Settings for the QAS, DT, and IU fields