COMFORTNET™ SYSTEM

F

URNACE

A

DVANCED

F

EATURES

M

ENUS

Submenu Item

Indication (for Display Only; not User Modifiable)

Number of Heat Stages (HT STG)

Displays the number of furnace heating stages

Input Rate (BTU/HR)

Displays the furnace input rate in kBtu/hr

Motor HP (1/2, ¾, or 1 MTR HP)

Displays the furnace indoor blower motor horsepower

CONFIGURATION

Submenu Item

Indication/User Modifiable Options

Comments

Fault 1 (FAULT #1)

Most recent furnace fault

For display only

Fault 2 (FAULT #2)

Next most recent furnace fault

For display only

Fault 3 (FAULT #3)

Next most recent furnace fault

For display only

Fault 4 (FAULT #4)

Next most recent furnace fault

For display only

Fault 5 (FAULT #5)

Next most recent furnace fault

For display only

Fault 6 (FAULT #6)

Least recent furnace fault

For display only

Clear Fault History (CLEAR)

NO or YES

Selecting “YES” clears the fault
history

NOTE: Consecutively repeated faults are shown a maximum of 3 times.

DIAGNOSTICS

Submenu Item

Indication (for Display Only; not User Modifiable)

Model Number (MOD NUM)

Displays the furnace model number

Serial Number (SER NUM)

Displays the furnace serial number (Optional)

Software (SOFTWARE)

Displays the application software revision

IDENTIFICATION

Submenu Item

User Modifiable Options

Comments

Heat Airflow Trim (HT TRM)

-10% to +10% in 2% increments,
default is 0%

Trims the heating airflow by the selected
amount.

Heat ON Delay (HT ON

5, 10, 15, 20, 25, or 30 seconds,
default is 30 seconds

Selects the indoor blower heat ON delay

Heat OFF Delay (HT OFF)

30, 60, 90, 120, 150, or 180 seconds,
default is 150 seconds

Selects the indoor blower heat OFF delay

Heat Airflow (HT ADJ)

1, 2, 3, or 4

Selects the nominal heating airflow (see
Startup Procedure and Adjustment –
Circulator Blower Speeds
for additional
information)

SET-UP

Submenu Item

Indication (for Display Only; not User Modifiable)

Mode (MODE)

Displays the current furnace operating mode

CFM (CFM)

Displays the airflow for the current operating mode

STATUS