beautypg.com

Goodman Mfg MVC95 User Manual

Page 20

background image

20

V

ENT

/F

LUE

P

IPE

& C

OMBUSTION

A

IR

P

IPE

24" MAX

3" MIN

24" MAX

AIR
INTAKE

12” MIN

SCREEN

12" MIN. TO ROOF OR

HIGHEST ANTICIPATED

SNOW LEVEL

90º MEDIUM

RADIUS ELBOW

Alternate Horizontal Vent Termination (Dual Pipe)

SUPPORT
STRAPS

VENT/FLUE

TEE

12" MIN. ABOVE

HIGHEST ANTICIPATED

SNOW LEVEL

12" MIN. ABOVE

HIGHEST ANTICIPATED

SNOW LEVEL

90° MEDIUM
RADIUS ELBOWS

SCREEN

COMBUSTION
AIR INTAKE

12" MIN

3" MIN

24" MAX

Standard Horizontal Terminations Above Anticipated Snow

Level (Dual Pipe)

SCREEN

12" MIN. TO ROOF OR

HIGHEST ANTICIPATED

SNOW LEVEL

Alternate Vent Termination Above Anticipated Snow Level

(Dual Pipe)

In a basement installation, the pipes may be run between the joist
spaces. If the pipes must go below the joist and then up into the
last joist space to penetrate the header, two 45° elbows should be
used to reach the header rather than two 90° elbows.

V

ENT

/I

NTAKE

T

ERMINATIONS

F

OR

I

NSTALLATION

OF

M

ULTIPLE

D

IRECT

V

ENT

F

URNACES

If more than one direct vent furnace is to be installed vertically
through a common roof top, maintain the same minimum clear-
ances between the exhaust vent and air intake terminations of
adjacent units as with the exhaust vent and air intake terminations
of a single unit.

If more than one direct vent furnace is to be installed horizontally
through a common side wall, maintain the clearances as in the
following figure. Always terminate all exhaust vent outlets at the
same elevation and always terminate all air intakes at the same
elevation.

Vents

24" Max.

3" Min.

12" Min.

Screen

24" Max.

Air

Intakes

90°
Medium
Radius
Elbows

24" Max.

3" Min.

3" Min.

12" MIN. ABOVE

HIGHEST ANTICIPATED

SNOW LEVEL

Horizontal Venting Of Multiple Units

C

ONCENTRIC

V

ENT

T

ERMINATION

Refer to the directions provided with the Concentric Vent Kit (DCVK)
for installation specifications.

S

IDE

W

ALL

V

ENT

K

IT

This kit is to be used with 2” or 3” direct vent systems. The vent kit
must terminate outside the structure and may be installed with the
intake and exhaust pipes located side-by-side or with one pipe
above the other. This kit is NOT intended for use with single pipe
(indirect vent) installations.

Refer to the directions furnished with the Side Wall Vent Kit
(p/n 0170K00000S) for installation specifications.