Goodman Mfg MVC95 User Manual

Page 12

background image

12

P

ROPANE

G

AS

/H

IGH

A

LTITUDE

I

NSTALLATIONS

A

LTERNATE

E

LECTRICAL

AND

G

AS

L

INE

C

ONNECTIONS

This furnace has provisions allowing for electrical and gas line con-
nections through either side panel. In horizontal applications the
connections can be made either through the “top” or “bottom” of
the furnace.

D

RAIN

P

AN

A drain pan must be provided if the furnace is installed above a
conditioned area. The drain pan must cover the entire area under
the furnace (and air conditioning coil if applicable).

F

REEZE

P

ROTECTION

Refer to Horizontal Applications and Conditions - Drain Trap and
Lines.

F

URNACE

S

USPENSION

If the furnace is installed in a crawl space it must be suspended
from the floor joist or supported by a concrete pad. Never install
the furnace on the ground or allow it to be exposed to water. Refer
to Location Requirements and Considerations - Furnace Suspen-
sion
for further details.

P

ROPANE

G

AS

/H

IGH

A

LTITUDE

I

NSTALLATIONS

WARNING

P

OSSIBLE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

 

MAY

 

OCCUR

 

IF

 

THE

 

CORRECT

 

CONVERSION

 

KITS

 

ARE

 

NOT

 

INSTALLED

. T

HE

 

APPROPRIATE

 

KITS

 

MUST

 

BE

 

APPLIED

 

TO

 

ENSURE

 

SAFE

 

AND

 

PROPER

 

FURNACE

 

OPERATION

. A

LL

 

CONVERSIONS

 

MUST

 

BE

 

PERFORMED

 

BY

 

A

 

QUALIFIED

 

INSTALLER

 

OR

 

SERVICE

 

AGENCY

.

This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
and orifice change to compensate for the energy content differ-
ence between natural and propane gas.

High altitude installations may require both a pressure switch and
an orifice/spring change. These changes are necessary to com-
pensate for the natural reduction in the density of both the gas fuel
and the combustion air at higher altitude.

For installations above 7000 feet, please refer to your distributor
for required kit(s).

H igh

Stage

Lo w

Stage

Natural

None

#43

3.5" w.c.

1.9" w.c.

None

Propane

LPM -05*

1

LPM -06*

2

#55

10.0" w.c.

6.0" w.c.

None

1

LPM -05* supports White-Rodgers 2-stage valve only

2

LPM -06* supports both Honeywell and White-Rodgers 2-stage valves

Orif ice

N OT E: In Canada, gas furnaces are only certified to 4500 feet.

Gas

0-7000

M anifo ld P ressure

P ressure

Switch

C hange

A lt itude

Kit

Contact the distributor for a tabular listing of appropriate
manufacturer’s kits for propane gas and/or high altitude installa-
tions. The indicated kits must be used to insure safe and proper
furnace operation. All conversions must be performed by a quali-
fied installer, or service agency.

V

ENT

/F

LUE

P

IPE

& C

OMBUSTION

A

IR

P

IPE

F

AILURE

 

TO

 

FOLLOW

 

THESE

 

INSTRUCTIONS

 

CAN

 

RESULT

 

IN

 

BODILY

 

INJURY

 

OR

 

DEATH

. C

AREFULLY

 

READ

 

AND

 

FOLLOW

 

ALL

 

INSTRUCTIONS

 

GIVEN

 

IN

 

THIS

 

SECTION

.

WARNING

U

PON

 

COMPLETION

 

OF

 

THE

 

FURNACE

 

INSTALLATION

CAREFULLY

 

INSPECT

 

THE

 

ENTIRE

 

FLUE

 

SYSTEM

 

BOTH

 

INSIDE

 

AND

 

OUTSIDE

 

OF

 

THE

 

FURNACE

 

TO

 

ASSURE

 

IT

 

IS

 

PROPERLY

 

SEALED

. L

EAKS

 

IN

 

THE

 

FLUE

 

SYSTEM

 

CAN

 

RESULT

 

IN

 

SERIOUS

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

EXPOSURE

 

TO

 

FLUE

 

PRODUCTS

INCLUDING

 

CARBON

 

MONOXIDE

.

WARNING

A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place.
Because of the relatively low flue gas temperature and water con-
densation requirements, PVC pipe is used as venting material.

This furnace must not be connected to Type B, BW, or L vent or
vent connector, and must not be vented into any portion of a fac-
tory built or masonry chimney except when used as a pathway for
PVC as described later in this section. Never common vent this
appliance with another appliance or use a vent which is used by a
solid fuel appliance. Do not use commercially available “no hub
connectors” other than those shipped with this product.

It is the responsibility of the installer to follow the manufacturers’
recommendations and to verify that all vent/flue piping and connec-
tors are compatible with furnace flue products. Additionally, it is
the responsibility of the installer to ensure that all piping and con-
nections possess adequate structural integrity and support to pre-
vent flue pipe separation, shifting, or sagging during furnace opera-
tion.

D

UAL

C

ERTIFICATION

: N

ON

-D

IRECT

/D

IRECT

V

ENT

This furnace is dual certified and may be installed as a non-direct
vent (single pipe) or direct vent (dual pipe) appliance. A non-direct
vent
installation requires only a vent/flue pipe, while a direct vent
installation requires both a vent/flue pipe and a combustion air
intake pipe. Refer to the appropriate section for details concerning
piping size, length, number of elbows, furnace connections, and
terminations.