Standard Connections

OR

OR

UPFLOW COUNTERFLOW

A

LTERNATE

F

URNACE

C

ONNECTIONS

If the standard locations are undesirable for a specific installation,
alternate side panel locations are available for both combustion air
inlet and vent/flue pipe connections. These locations may be of
particular benefit to upright upflow installations requiring additional
access to an A coil, or to upright counterflow installations requiring
additional access to a filter or electronic air cleaner, or to horizontal
installations desiring vent/flue (and combustion air intake) piping
run vertically from the side of the cabinet.

NOTE: Standard and alternate locations can be combined (i.e.,
an installation may use the standard combustion air intake loca-
tion but use the alternate vent/flue location or vice versa), if needed.

E

DGES

 

OF

 

SHEET

 

METAL

 

HOLES

 

MAY

 

BE

 

SHARP

. U

SE

 

GLOVES

 

AS

 

A

 

PRECAUTION

 

WHEN

 

REMOVING

 

HOLE

 

PLUGS

.

WARNING

A

LTERNATE

V

ENT

/F

LUE

L

OCATION

The alternate vent/flue location is the large hole directly in line with
the induced draft blower outlet. To use the alternate vent/flue loca-
tion refer to the following steps and the “Alternate Vent/Flue Loca-
tion” figure.
NOTE: Counterflow instructions follow the upflow instructions.

1. Remove and save the four screws securing the vent/flue

coupling to the furnace top panel.
Counterflow units.
Remove and save the four screws securing the vent/flue
coupling to the furnace basepan. Also remove the three
screws securing the furnace’s internal vent/flue piping to
the blower deck.

2. Upflow and Counterflow units.

Loosen the worm gear hose clamps on the rubber elbow
and detach it from both the induced draft blower and the
vent/flue pipe.

3. Upflow and Counterflow units.

Remove the vent/flue pipe from the furnace.

4. Cut the vent/flue pipe 3.75 inches from the flanged end of

the pipe (see “Vent/Flue Pipe Cuts” figure). The section of
pipe attached to the coupling will reach through the side
panel to the induced draft blower. Discard remaining pipe
and elbows.

Counterflow units.

Cut the vent/flue pipe 3.75 inches from the blower deck
coupling (see “Vent/Flue Pipe Cuts” figure). Save vent/flue
pipe attached to blower deck coupling for use in the alternate
location. Discard remaining pipe and elbows.

FLANGE

CUT

HERE

3.75"

Vent/Flue Pipe Cuts

5. Remove plastic plug from alternate vent/flue location.

Relocate and install plug in standard vent/flue location (top
cover).
Counterflow units.
Remove plastic plug from alternate vent/flue location.
Relocate and install plug in standard vent/flue location
(basepan). Plug remaining hole in blower deck with plastic
plug included in the drain kit bag.

6. Upflow and Counterflow units.

Insert cut section of vent/flue pipe and coupling into alternate
vent/flue location. Using a rubber coupling and worm gear
hose clamps from the drain kit bag, attach the vent/flue
pipe and coupling to the induced draft blower. Secure the
coupling to the cabinet using the screws removed in step 1
or with field-supplied 3/8” #8 self drilling screws.

T

HE

 

RUBBER

 

ELBOW

 

IS

 

NOT

 

DESIGNED

 

TO

 

SUPPORT

 

A

 

LOAD

. W

HEN

 

THE

 

RUBBER

 

ELBOW

 

IS

 

MOUNTED

 

EXTERNALLY

 

TO

 

THE

 

FURNACE

 

CABINET

EXTREME

 

CARE

 

MUST

 

BE

 

TAKEN

 

TO

 

ADEQUATELY

 

SUPPORT

 

FIELD

SUPPLIED

 

VENT

/

FLUE

 

PIPING

AS

 

DAMAGE

 

CAN

 

RESULT

 

IN

 

LEAKS

 

CAUSING

 

BODILY

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

EXPOSURE

 

TO

 

FLUE

 

GASES

INCLUDING

 

CARBON

 

MONOXIDE

WARNING

7. Upflow and Counterflow units.

For upright installations, externally mount the rubber
elbow to the vent/flue coupling using a worm gear hose
clamp. Secure field supplied vent/flue piping to the rubber
elbow using a worm gear hose clamp. NOTE: Use of the
alternate vent/flue location for upright installations, requires
the drain trap be installed on the same side of the unit as
the flue pipe.