TARTUP

P

ROCEDURE

& A

DJUSTMENT

Honeywell Model VR9205 (Two-Stage)

i

Manometer

Manometer

Hose

Common
Terminal(C)

High Fire Coil
Terminal (HI)

Low Fire Coil
Terminal (LO)

Inlet Pressure Tap
1/8 NPT

Open to

Atmosphere

Outlet Pressure Tap
1/8 NPT

Honeywell Model VR9205 Connected to Manometer

1. Turn OFF gas to furnace at the manual gas shutoff valve

external to the furnace.

2. Connect a calibrated water manometer (or appropriate gas

pressure gauge) at either the gas valve inlet pressure boss
or the gas piping drip leg. See Honeywell VR9205 gas valve
figure or White-Rodgers 36G54 gas valve figure for location
of inlet pressure boss.

NOTE: If measuring gas pressure at the drip leg or Honeywell
VR9205 gas valve, a field-supplied hose barb fitting must be installed
prior to making the hose connection. If using the inlet pressure
boss on the White-Rodgers 36G54 gas valve, then use the 36G
Valve Pressure Check Kit, Goodman Part No. 0151K00000S.

3. Turn ON the gas supply and operate the furnace and all

other gas consuming appliances on the same gas supply
line.

4. Measure furnace gas supply pressure with burners firing.

Supply pressure must be within the range specified in the
Inlet Gas Supply Pressure table.

Natural Gas

Minimum: 5.0" w.c.

Maximum:10.0" w.c.

Propane Gas Minimum: 11.0" w.c.

Maximum:13.0" w.c.

Inlet Gas Supply Pressure

If supply pressure differs from table, make the necessary adjust-
ments to pressure regulator, gas piping size, etc., and/or consult
with local gas utility.

5. Turn OFF gas to furnace at the manual shutoff valve and

disconnect manometer. Reinstall plug before turning on
gas to furnace.

6. Turn OFF any unnecessary gas appliances stated in step

3.

Gas Line

Gas
Shutoff

Valve

Gas Line
To Furnace

Drip Leg Cap
With Fitting

Manometer Hose

Manometer

Open To
Atmosphere

Measuring Inlet Gas Pressure (Alt. Method)

G

AS

M

ANIFOLD

P

RESSURE

M

EASUREMENT

AND

A

DJUSTMENT

T

O

 

PREVENT

 

UNRELIABLE

 

OPERATION

 

OR

 

EQUIPMENT

 

DAMAGE

THE

 

GAS

 

MANIFOLD

 

PRESSURE

 

MUST

 

BE

 

AS

 

SPECIFIED

 

ON

 

THE

 

UNIT

 

RATING

 

PLATE

. O

NLY

 

MINOR

 

ADJUSTMENTS

 

SHOULD

 

BE

 

MADE

 

BY

 

ADJUSTING

 

THE

 

GAS

 

VALVE

 

PRESSURE

 

REGULATOR

.

CAUTION

Only small variations in gas pressure should be made by adjusting
the gas valve pressure regulator. The manifold pressure must be
measured with the burners operating. To measure and adjust the
manifold pressure, use the following procedure.

1. Turn OFF gas to furnace at the manual gas shutoff valve

external to the furnace.

2. Turn off all electrical power to the system.
3. Outlet pressure tap connections:

a. Honeywell VR9205 valve: Remove the outlet pressure

boss plug. Install an 1/8" NPT hose barb fitting into the
outlet pressure tap.

b. White-Rodgers 36G54 valve: Back outlet pressure test

screw (inlet/outlet pressure boss) out one turn
(counterclockwise, not more than one turn).

4. Attach a hose and manometer to the outlet pressure barb

fitting (Honeywell valve) or outlet pressure boss (White-
Rodgers valve).

5. Turn ON the gas supply.
6. Turn on power and close thermostat “R” and “W1” contacts

to provide a call for low stage heat.

7. Measure the gas manifold pressure with burners firing.

Adjust manifold pressure using the Manifold Gas Pressure
table shown below.

8. Remove regulator cover screw from the low (LO) outlet

pressure regulator adjust tower and turn screw clockwise
to increase pressure or counterclockwise to decrease
pressure. Replace regulator cover screw.