Horizontal installations with the left side panel down will require
drain hoses to be connected to the left side front cover drain port
and the side drain port on the rubber elbow.

1. Remove the rubber plug/cap from the front cover left (down)

side drain port.

2. Relocate the front cover pressure switch hose connection

from the right side (as shipped) pressure tap to the left
(down) side tap. The pressure switch hose must be
connected to the down side to guard against blocked drain
conditions. Cut hose to appropriate length to minimize
sagging. Plug right (unused) pressure tap with plug
removed from left side.

3. Secure Hose A to front cover drain port with a red hose

clamp. Route hose to rear left (down) side panel grommet
holes. NOTE: For left side drainage, grommets must be
relocated to left side panel.

4. Remove the rubber cap from the side drain port on the

rubber elbow.

5. Secure the short end of Hose B to rubber elbow side drain

port using a green hose clamp. NOTE: For left side
drainage, route hose to far left (down) side panel grommet
holes. NOTE: Horizontal left side connections (when using
new side port drain elbow) does not require connecting a
hose to the induced draft blower housing.

6. Cut 5 1/2 inches straight length from the long end of each

Tube 2 and discard radius ends.

7. Insert approximately one inch of each Tube 2 through left

side panel grommet hole. Secure tubes to Hose A and
Hose B with a green hose clamps. NOTE: Tube must
reach bottom of trap. Ensure hoses and tubes maintain a
downward slope for proper drainage and that they are not
kinked or binding.

For details concerning mounting of the drain trap, refer to Con-
densate Drain Lines and Drain Trap - Horizontal Drain Trap Mount-
ing.

H

ORIZONTAL

D

RAIN

T

RAP

M

OUNTING

(L

EFT

OR

R

IGHT

S

IDE

P

ANEL

)

1. Position the drain trap against side panel with drain tubes

inserted into trap. Note that the trap may be orientated
with the outlet facing either the furnace’s top cover or base
pan.

2. Secure drain trap to side panel at the dimples or crosshairs

located on either side of the grommet drain holes.

3. Confirm that tubes reach bottom of drain trap and that all

hoses maintain a downward slope and are not kinked or
binding.

4. Attach PVC drain line to drain trap outlet with either a 90°

elbow or coupling.

LEFT SIDE

PANEL

FRONT COVER

DRAIN PORT

SIDE PANEL

GROMMET

HOLES

DRAIN TRAP

TUBE(S) 2

GREEN HOSE

CLAMP

HOSE A

HOSE B

FRONT

COVER

PRESSURE

TAP

RED HOSE CLAMP

GREEN HOSE

CLAMP

Horizontal Connections - Left Side Down

(Upflow Shown, Counterflow Similar)