5.3 Host Commands
Table 5.28 WRITE SAME (2/2)
Byte Name Value
Description
Count
(8 byte) Number of Sectors
014h
to
017h
Pattern (4
byte)
If the Function Code is 0001h, this field contains a 32-
bit pattern that is written on the media.
018h
to
1FFh
(Reserved) -
Reserved
00Ch
to
013h
* It is invalid excluding the description value.
Name
Table 5.29 ERROR RECOVERY CONTROL
Byte
Value
Description
000h
001h
Action Code
0003h
ERROR RECOVERY CONTROL
0001h
Set New Value
The retry processing when making an error in the
specified timer
002h
003h
Function Code
0002h
Return Current Value
The timer value of the error recovery being set now is
displayed in SN /SC field.
0001h Read
Timer
005h
Selection Code
0002h Write
Timer
006h
007h
Value (2
byte)
Set to Timer Value (x 100 ms)
Minimum value is 10 sec.
(ex.) 0000h: Disable timeout
0063h: Invalid
0064h: 10000 ms (10 s)
008h
to
1FFh
(Reserved) -
Reserved
004h
* It is invalid excluding the description value.
C141-E249