beautypg.com

3 host commands, 1 command code and parameters – FUJITSU MHW2120BS User Manual

Page 103

background image

5.3 Host Commands

5.3 Host Commands

The host system issues a command to the device by writing necessary parameters
in related fileds in the shadow block registers and writing a command code in the
Command field of the shadow block registers.

The device can accept the command when the BSY bit is 0 (the device is not in the
busy status).

The host system can halt the uncompleted command execution only at execution
of COMRESET or software reset.

When the BSY bit is 1 or the DRQ bit is 1 (the device is requesting the PIO data
transfer) and the host system writes to the command field of the shadow block
register, the correct device operation is not guaranteed.

5.3.1 Command code and parameters

Table 5.6 lists the supported commands, command code and the related fields to
be written necessary parameters at command execution.

Table 5.6 Command code and parameters (1/3)

COMMAND CODE (Bit)

PARAMETER USED

COMMAND NAME

7 6 5 4 3 2 1 0 FR SC

SN

CY DH

RECALIBRATE

0 0 0 1 X X X X N N N N D

READ

SECTOR(S)

0 0 1 0 0 0 0 R N Y Y Y Y

WRITE

SECTOR(S)

0 0 1 1 0 0 0 R N Y Y Y Y

WRITE

VERIFY

0 0 1 1 1 1 0 0 N Y Y Y Y

READ

VERIFY

SECTOR(S)

0 1 0 0 0 0 0 R N Y Y Y Y

SEEK

0 1 1 1 X X X X N N Y Y Y

EXECUTE

DEVICE

DIAGNOSTIC 1 0 0 1 0 0 0 0 N N N N N

INITIALIZE

DEVICE

PARAMETERS 1 0 0 1 0 0 0 1 N Y N N Y

DOWNLOAD

MICROCODE

1 0 0 1 0 0 1 0 Y Y Y N D

STANDBY IMMEDIATE

1
1

0
1

0
1

1
0

0
0

1
0

0
0

0
0

N N N N D

IDLE IMMEDIATE

1
1

0
1

0
1

1
0

0
0

1
0

0
0

1
1

Y N Y Y D

UNLOAD IMMEDIATE

1
1

0
1

0
1

1
0

0
0

1
0

0
0

1
1

Y N Y Y D

STANDBY

1
1

0
1

0
1

1
0

0
0

1
0

1
1

0
0

N Y N N D

C141-E249

5-29

This manual is related to the following products: