5.3 Host Commands

(7)

EXECUTE DEVICE DIAGNOSTIC (X’90’)

This command performs an internal diagnostic test (self-diagnosis) of the device.

The device reports the diagnostic result and status to the host.

Table 5.7 lists the diagnostic code written in the Error field which is 8-bit code.

Table 5.7 Diagnostic code

Code

Result of diagnostic

X’00’
X’01’
X’02’
X’03’
X’04’
X’05’
X’06’

Format Unit is not completed.
No error detected.
HDC diagnostic error
Data buffer diagnostic error
Memory diagnostic error
Reading the system area is abnormal
Calibration abnormal

Note:

The device responds to this command with the result of
power-on diagnostic test.

Error reporting conditions

(1) A SATA communication error occurred (ST = 51h, ER = 14h).

At command issuance (Shadow Block Registers setting contents)

CM

1 0 0 1 0 0 0 0

DH

x x x x

HD

No.

/LBA

CH

CL
SN

SC
FR

xx
xx
xx
xx
xx

At command completion (Shadow Block Registers contents to be read)

ST Status

information

DH

x x x x

HD

No.

/LBA

CH)

CL
SN

SC

ER

xx
xx

01H
01H

Diagnostic code