Safety input specifications – IDEC FS1A Controller User Manual
Page 16

2-7
Safety input specifications
Drive terminal specifications (T0, T1, T2, T3, T4, T5, T6, T7, T10, T11, T12, T13, T14, T15)
Rated drive voltage
Power supply voltage
Minimum drive voltage
Power supply voltage – 2.0V
Number of drive terminals
14
Maximum drive current
20mA per port (at 28.8V DC)
Note1
Receive terminal specifications (X0, X1, X2, X3, X4, X5, X6, X7, X10, X11, X12, X13, X14, X15)
Rated input voltage
24V DC
Input ON voltage
15.0V DC to 28.8V DC
Input OFF voltage
Open or 0V DC to 5.0V DC
Number of receive terminals
14
Rated input current
10mA per port (at rated voltage)
Type of input
Sink type input (for PNP output), Type 1(IEC/EN 61131-2)
Wiring specifications
Cable length
Note2
100m maximum (total wiring length per 1 input)
Allowable wiring resistance
300Ω maximum
Note1. The drive port generates check pulses in order to diagnose input devices and internal
circuits. (Wiring and the diagnostic function are different depending on the logic selected.
See “Chapter 5 LOGIC” for details. But the basic function is same.)
Note2. For cables longer than 30m between SafetyOne and connected devices, or wiring drive
terminals and receive terminals separately, use grounded shielded cables to assure
electromagnetic compatibility.
T
n
T
n+1
X
n+1
X
n
SafetyOne
In case of multiple safety input devices are connected
・・・
・・・
・・・
Safety input equivalent circuit Safety input operating range
X
n
Int
e
rna
l C
ir
c
uit
2.2kΩ
V -
Voltage(V)
Current
(mA)
28.8
24
15
5
1 6
10
12
ON area
Transition area
OFF area