FEC DSP1500 (SAN3) User Manual
Page 7

enFORCE
SAN Unit Operation Manual
PAGE 6 - 7
Chapter 6: System Operation
6.3 RUN Status Mode Operating Instruction
The
enFORCE
System has two operational states which are selected with the RUN/BYPASS
switch on the front of the SAN Unit or by the PLC Bypass input. When the RUN/BYPASS switch is in
the RUN position or when the PLC Bypass input is low (OFF), the unit is in RUN status.
In the RUN status, press results, abnormalities and preset values are displayed.
6.3.1 Run Status Display
「
DATA」
Displays the press result and data setting.
Displays the load value of the load transducer when in Real Time Display Mode.
「
PARM」
Displays the operating parameter number.
Displays the abnormal number when abnormalities occur.
「
D-NO」
Displays the data number displayed on「DATA」.
1 figure display : Real-time Display Mode
left side figure
: Press Result Display Mode
2 figure display : Parameter Display Mode
Displays the abnormal sub-code when abnormalities occur.
■ Parameter Number: 1, Data Number: 10
■ Abnormal Number: 1, Sub Code: 0
■ When [CAL] button is pressed with full-scale load not set or when the connected tool
number is wrong.
■ When resetting immediately after powering-up, a press unit number is displayed.