Chapter 6: System Operation
6.5 Setting Up a Parameter for Returning
It is recommended that, if the return of the press is done with a parameter, use Distance Control.
However, if Target Distance is set to 0 without a return operation, the press will reject because the
Distance Low value is zero (a value less than zero is not possible).
Refer to the following for setting up a Return Parameter. Adjustments can be made according to
the individual application.
D-NO DATA
SETTING
00
Press
Operation
0001
(Distance Control+Return Operation)
11
Load Low Limit
0
12
Load High Limit
Maximum Load of the Tool
14
Press Speed Start Load
1 or Maximum Load of the Tool
15
Interference Check Load
Maximum Load of the Tool
16
Distance Measurement Start Load 0
17
Part Check Low
Maximum Load of the Tool
20
Distance Low Limit
0
21
Distance High Limit
2
22
Target
Distance
1
(setting to 0 will cause a reject)
23
Interference Check Distance
3
24
Press Speed Start Distance
2
30
Advance Position ON Distance
0
31
Advance Position OFF Distance
0
(if using Rates, set to maximum)
32
Return Position ON Distance
0
33
Return Position OFF Distance
0
(if using Rates, set to maximum)
40
Slow Start Time
0
41
1
St
Time High
120
42
2
nd
Time High
120
50
Slow Start Speed
1
51
Approach Speed
100
52
Part Search Speed
5
53
Press Speed
3
54
Return Speed
5
60
Approach
Distance
10
(may need to set larger for higher speeds)
61
Load Hold Time
0
62
Job Start Position
0
64
Distance
Offset
0