FEC DSP1500 (SAN3) User Manual
Page 44

enFORCE
SAN Unit Operation Manual
PAGE 6 - 44
Chapter 6: System Operation
A Step Press is a press operation that is done in multiple phases using multiple parameters. This
operation works best when used in conjunction with the “Keep Load” Return Operation. For best
results set up as follows:
For a smooth curve, set [18: Time Start Load] equal to the previous step’s [13: Target
Load].
Turn On the Self Check Off signal before starting each cycle.
After the end of each phase, start the next phase as soon as possible. Because load
hold is not used, the press motor will turn off and the press will begin releasing the load
gradually.
The present load value will be fixed to 0 point and operate unless the
SELF-CHECK signal is turned OFF for this operation.
*There is a possibility to destroy the equipment.
This press can be done with the F type tool but make sure not to
overload.
Load
Parameter 1
Final Position
Time/
Distance
Parameter 2
Parameter 3
Parameter 4
Step Press Operation using the Time Controlled Press Method