FEC DSP1500 (SAN3) User Manual
Page 26

enFORCE
SAN Unit Operation Manual
PAGE 6 - 26
Chapter 6: System Operation
♦
Distance Control (Method 1)
Upon start of cycle, the press will operate until it achieves [22: Target Distance].
During the press cycle, checks are performed for “Interference Check” / “Part Check”,
Load and Distance. If any of these values are compromised, the press will stop and
return as programmed.
(See corresponding sections for Interference Check and Part Check explanations.)
If “Interference Check” or “Part Check” are not used, set [15: Interference Check
Load / Part Check Load High] and [17: Part Check Load Low] to [10: CAL
Load] and [23: Interference Check Distance / Part Check Distance] to a
minimum of [21: Distance High Limit].
Review Speed Section explanations and cautions when setting [15: Interference
Check Load / Part Check Load High], [14: Press Speed Start Load], [24: Press
Speed Start Distance] and [20: Approach Distance].
Load
Distance
[12]
Load High Limit
[16] Distance Measurement
Start Load
[11] Load Low Limit
[15] Part Check Load High
(Interference Check Load)
[17] Part Check Load Low
[20]
Distance
Low Limit
[21]
Distance
High Limit
[23]
Part Check Distance
(Interference Check Distance)
Part Check - High
(Interference Zone)
Final Judgment Zone
[22]
Target
Distance
Part Check - Low