FEC DSP1500 (SAN3) User Manual
Page 34

enFORCE
SAN Unit Operation Manual
PAGE 6 - 34
Chapter 6: System Operation
Final Load Low Limit Judgment Disable [ 0 ]
Judgment of a “Low Load” condition at the end of the press cycle will not be reported.
All other judgments will be reported.
Final Load Low Limit Judgment Enable [ 1 ]
Judgment of a “Low Load” condition at the end of the press cycle will be reported.
All other judgments will be reported.
Part Check + Final Load Low Judgment [ 3 ]
All programmed judgments will be performed. This selection also enables the “Part
Check” functionality.
At [23: Part check Distance], the judging of an abnormally high or low load is possible.
If a load value greater than [15: Part Check Load High] is sensed before the press
exceeds [23: Part Check Distance], a “1
ST
Zone High” reject will occur and press
operation will stop.
Upon reaching [23: Part Check Distance], if [17: Part Check Load Low] has not
been reached, a “1
ST
Zone Low” reject will occur and press operation will stop.
Judgment Operation
Part Check - Low Load Zone
(Under Tolerance or No Part)
Part Check - High Load Zone
(Over Tolerance or Obstruction)
Load
[15] Part Check
Load High
[23] Part Check Distance
[17] Part Check
Load Low
Distance
Part Check