FEC DSP1500 (SAN3) User Manual
Page 17

enFORCE
SAN Unit Operation Manual
PAGE 6 - 17
Chapter 6: System Operation
6.4.3 Parameter Copying
To speed data entry, it may be beneficial to copy from one parameter set to another parameter set.
This is especially convenient in the case where minor changes must be made to parameters
sharing common data. Refer to the example procedure below to copy between parameters using
the Display Panel:
(
1)Selecting the Parameter and Data Number.
When in Setup Mode, select Parameter 00 and D-No. 01. The number shown in the
[DATA] display reflects the “SP Version” and is read only. It cannot be changed. However,
the [DATA] fields are available for changing allowing a copying of data from the parameter
shown in the first two [DATA] fields to the parameter shown in the last two [DATA] fields. In
the following example we want to copy data from Parameter 04 to Parameter 05. Press
the MODE button to begin changing data.
(
2)Enter the Parameter you want to copy from.
The cursor will be flashing in the first position allowing changes to the “tens” digit of the
“From” parameter. Press the [↑] or [↓] button until “0” is shown. Press the MODE button to
move to the next cursor position.
The cursor will move to the second position allowing changes to the “ones” digit. Press
the [↑] or [↓] button until “4” is shown. Press the MODE button to move to the next cursor
position.
(
3)Enter the Parameter you want to copy to.
The cursor will be flashing in the third position allowing changes to the “tens” digit of the
“To” parameter. Press the [↑] or [↓] button until “0” is shown. Press the MODE button to
move to the next cursor position.
The cursor will move to the fourth position allowing changes to the “ones” digit. Press the
[↑] or [↓] button until “5” is shown. Press the SET button to proceed with the copy.
(
4)Confirm the Copy.
The [DATA] display will show “CHnG.” and “nO” will appear on the “D-NO” display.
Press the [↑] or [↓] button until yES is shown. Confirm the parameter copy by pressing
the [SET] button. (If no action is taken within 5 seconds, the display will return to the
Setup Mode and no changes will take place.)
MODE
MODE
MODE
(2)
↑
↓
Setup Mode
SET
MODE
(1)
From
To
From
To
From
To
SET
(2)
(3)
(3)
(3)
(4)
(4)