Distance Control with Load Limit (Method 7)
Upon start of cycle, the press will operate until it achieves [22: Target Distance].
During the press cycle, after achieving [13: Target Load], the press rate will be current
controlled to hold [13: Target Load] until [22: Target Distance] is reached. During the
press cycle, checks are performed for “Interference Check” / “Part Check”, Load and
Distance. If any of these values are compromised, the press will stop and return as
programmed.
(See corresponding sections for Interference Check and Part Check explanations.)
If “Interference Check” or “Part Check” are not used, set [15: Interference Check
Load / Part Check Load High] and [17: Part Check Load Low] to [10: CAL
Load] and [23: Interference Check Distance / Part Check Distance] to a
minimum of [21: Distance High Limit].
Review Speed Section explanations and cautions when setting [15: Interference
Check Load / Part Check Load High], [14: Press Speed Start Load], [24: Press
Speed Start Distance] and [20: Approach Distance].
Load
Distance
[12] Load High Limit
[11] Load Low Limit
[13] Target Load
[15] Part Check Load High
(Interference Check Load)
[17] Part Check Load Low
[20]
Distance
Low Limit
[21]
Distance
High Limit
[23]
Part Check Distance
(Interference Check Distance)
Part Check - High
(Interference Zone)
Final Judgment Zone
[22]
Target
Distance
Part Check - Low