FEC DSP1500 (SAN3) User Manual
Page 11

enFORCE
SAN Unit Operation Manual
PAGE 6 - 11
Chapter 6: System Operation
6.3.5 Press Result Display Mode
The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.
D-NO DATA UNIT
_0
Peak Load Value(Judgment Load Value) KN
_1
Final Distance Value
mm
_2
(Not Used) 1
st
Load Rate Value
KN/mm
_3
(Not Used) 2
nd
Load Rate Value
KN/mm
_4
1
st
Region Operating Time
Sec
_5
Final Region Operating Time
Sec
_6
Cycle Time
Sec
_7
Operation Mode Number
_8
Thermal value at Operation End (abnormal occurs if greater than 100)
_9
Lower 4 digits of final distance value (v1.96 or later)
-0
Press Method Number
-1
Step
-2
Distance when Press Speed Load was Detected (v1.96 or later)
mm
-3
Self Check ON: performed OFF: not performed
-4
Speed when Speed Change Load was Detected (v1.96 or later)
mm/sec
-5
Cause of press stop
0: Reset/No Data/After manual operation 1: Abnormal
2: BYPASS signal 3: STOP signal 4: REJECT
5: ACCEPT signal 6: START signal OFF * 7: CW signal *
8: CCW signal * *(v1.96 or later)
-6
Load Judgment Ld (Blank=Accept, H=High Reject, L=Low Reject)
-7
Distance Judgment dS (Blank=Accept, H=High Reject, L=Low Reject)
-8
Load Rate Judgment rt (Blank=Acc., H=High Rej., L=Low Rej., Z=1
st
Zone)
-9
Time Judgment Γi (1
ST
, 2
ND
)
(Blank=Accept, H=High Reject)
=0
(Not Used) 1
ST
Load Rate Area Increment Load
KN
=1
(Not Used) 2
ND
Load Rate Area Increment Load
KN
=2
(Not Used) 1
ST
Final Load
KN
=3
(Not Used) 1
ST
Peak Load
KN
=4
Final Load Value
KN
=5
Distance at Peak Load (judgment load) mm
「
D-NO」 「DATA」
Peak load value
Final Distance value
1ST Load Rate
Distance at Peak Load
D-NO
:
left side figure
0
1
2
5
[↑] / [↓]
buttons