FEC DSP1500 (SAN3) User Manual
Page 22

enFORCE
SAN Unit Operation Manual
PAGE 6 - 22
Chapter 6: System Operation
¾
Data Number
0B
Approach Distance Limit/Load Cell Availability
This data field sets the maximum approach distance and availability of the load cell.
□ □ □ □
Load Cell Availability
0: With Load Cell (Default)
1: Without Load Cell
Approach Distance Limit (Default = 000)
If you set 200, the approach distance will be up to 200mm.
*Example: If the load transducer is used and the approach distance limit is 200mm, the
setting will be 2000.
¾
Data Number
0C
Current Load Conversion Ratio [percentage] (Default = 100)
This data field sets the conversion ratio (as a percentage) of current control without the
load transducer.
A setting of 0~100 is possible.
¾
Data Number
0D
Stroke Distance Limit/Load Hold Time Decimal Point
It sets the maximum distance stroke allowed (except for approach distance) and decimal
point of the Load Hold Time.
□ □ □ □
Load Hold Time Decimal Point
0: X.X (Default) 1: no decimal point
Stroke Distance Limit (Default = 000)
If you set 200, distance settings other than approach distance
will be limited to 200mm.
*Example: If the stroke distance limit is 200mm and there is no decimal point required,
the setting will be 2001.
¾
Data Number
0E
Manual Operation Speed (Default = 10~30)
This data field sets the speed of MANUAL operations. The speed of the [home position
search], [home position return] and [high speed jog] is set to this speed.
*The maximum speed of the [home position search] is 10mm/sec.
The speed of the [middle speed jog] is 1/10 of the set value or the slowest speed of
the attached tool.
The speed of the [slow speed jog] is 1/100 of the set value or the slowest speed of the
attached tool.
¾
Data Number
0F
Dynamic Hold / RS232 Data Format / Speed Decimal Point
□ □ □ □
Speed Decimal Point
0: XXXX (no decimal point), 1: XXX.X, 2: XX.XX
Do not change the setting unless it is necessary
because the speed decimal point is fixed for each
tool when shipped.
RS-232C Equipment Data Format Setting
0: Printer 1: Monitor 2: LVDT(digital gauge)
Dynamic Hold
0: Dynamic Hold ON 1: Dynamic Hold OFF
If Dynamic Hold option is set to 1 (OFF), system will
automatically be set to SERVO OFF mode after the
operation has finished.
Special Specification
0: Normal
1: SAN2 Compatible Mode
2: The result data will not be reported for parameter number 32.
(For systems with Return function set on parameter 32)