SAN Unit Operation Manual

PAGE 6 - 22

Chapter 6: System Operation

¾

Data Number

0B

Approach Distance LimitLoad Cell Availability

This data field sets the maximum approach distance and availability of the load cell.

□ □ □ □

Load Cell Availability

0: With Load Cell (Default)

1: Without Load Cell

Approach Distance Limit (Default = 000)

If you set 200, the approach distance will be up to 200mm.

*Example: If the load transducer is used and the approach distance limit is 200mm, the
setting will be 2000.

¾

Data Number

0C

Current Load Conversion Ratio [percentage] (Default = 100)

This data field sets the conversion ratio (as a percentage) of current control without the
load transducer.

A setting of 0~100 is possible.

¾

Data Number

0D

Stroke Distance LimitLoad Hold Time Decimal Point

It sets the maximum distance stroke allowed (except for approach distance) and decimal
point of the Load Hold Time.

□ □ □ □

Load Hold Time Decimal Point

0: X.X (Default) 1: no decimal point

Stroke Distance Limit (Default = 000)

If you set 200, distance settings other than approach distance
will be limited to 200mm.

*Example: If the stroke distance limit is 200mm and there is no decimal point required,
the setting will be 2001.

¾

Data Number

0E

Manual Operation Speed (Default = 10~30)

This data field sets the speed of MANUAL operations. The speed of the [home position
search], [home position return] and [high speed jog] is set to this speed.
*The maximum speed of the [home position search] is 10mm/sec.

The speed of the [middle speed jog] is 1/10 of the set value or the slowest speed of
the attached tool.
The speed of the [slow speed jog] is 1/100 of the set value or the slowest speed of the
attached tool.

¾

Data Number

0F

Dynamic Hold / RS232 Data Format / Speed Decimal Point

□ □ □ □

Speed Decimal Point
0: XXXX (no decimal point), 1: XXX.X, 2: XX.XX

Do not change the setting unless it is necessary
because the speed decimal point is fixed for each
tool when shipped.

RS-232C Equipment Data Format Setting

0: Printer 1: Monitor 2: LVDT(digital gauge)

Dynamic Hold

0: Dynamic Hold ON 1: Dynamic Hold OFF

If Dynamic Hold option is set to 1 (OFF), system will
automatically be set to SERVO OFF mode after the
operation has finished.

Special Specification

0: Normal
1: SAN2 Compatible Mode
2: The result data will not be reported for parameter number 32.

(For systems with Return function set on parameter 32)