FEC DSP1500 (SAN3) User Manual
Page 24

enFORCE
SAN Unit Operation Manual
PAGE 6 - 24
Chapter 6: System Operation
6.4.4.2 Work Parameters: Parameter Number 01 to 32
Load
Settings
Distance
Settings
Time
Settings
Speed
Settings
Special Settings
¾
Data Number
00
Press Mode(Press Method+Judgment Operation+
Return Operation)
This data field will set the Press Method, Judgment Operation and Return Operation.
□ 0 □ □
Press Method
0: Load Control
1: Distance Control
2: Load Control – Specified Point Load Judgment /
Load Rise Detection
3: Load Control – Time Controlled Press
4: Load Control – Load Drop Detection
5: Load Control – Specified Range Peak Load Judgment
6: Load Control – Load Drop Detection (Point Stop)
7: Distance Control – With Load Limit
Judgment Operation
0: Final Load Low Limit Judgment Disable
1: Final Load Low Limit Judgment Enable
3: Part Check + Final Load Judgment
Return Operation
0: Return
1: [ACCEPT] Return, [REJECT] No Return
2: [ACCEPT] No Return, [REJECT] Return
3: Jog Return
4: Keep Load
5: Load Ignore Return
8: [ACCEPT] and [REJECT] No Return
9: Load Return (Software version 1.94 or later)
*For further detailed Press Mode instruction, see the following items.