15

CONTACT RATINGS

Contact Arrangement

1 Form C (SPDT)

max. Switch Power

max. Switch voltage

max. Switch current

125VA 60W

125VAC 30VDC

2A

Contact Resistance

100m

Resistive Load

1A/125VAC

2A/30VDC

Contact Material

AgNi10

External I/O Box pin signals

Pin #

Definition

1 INPUT

SIGNAL

1+

2 INPUT

SIGNAL

2+

3 INPUT

SIGNAL

3+

4 INPUT

SIGNAL

4+

5

OUTPUT 3 – Normally Closed

6 INPUT

SIGNAL

1-(GND)

7 INPUT

SIGNAL

2-(GND)

8 INPUT

SIGNAL

3-(GND)

9 INPUT

SIGNAL

4-(GND)

10

OUTPUT 3 – Common

11

OUTPUT 1 – Normally Open

AVerMedia LX5000 User’s Manual

16

12

OUTPUT 1 – Common

13

OUTPUT 2 – Normally Open

14

OUTPUT 2 – Common

15

OUTPUT 3 – Normally Open

Sensor Inputs

External sensors such as infrared sensors, smoke detectors, proximity

sensors, door sensors, etc., can be attached to the AVerMedia LX5000’s

input-signal connectors on the External I/O Box. These devices trigger

the system to respond with a predefined action (e.g. record video)

Relay Outputs

The AVerMedia LX5000’s output connectors (relay output) can be

attached to external output control devices such as alarms. The system

can be configured to activate or deactivate these devices. Each

AVerMedia video card supports three relay outputs. Two of them are

normally open relays with one being a toggle switch.