beautypg.com

AVerMedia Technologies LX5000 User Manual

Page 7

background image

AVerMedia LX5000 User’s Manual

13

Cameras need to be installed according to the numerical order displayed

on the diagrams above for each model. With the LX5000, cameras

will be installed from top to bottom beginning with the left-most

column.

2.4 Connecting External Inputs/Outputs Control Devices

Each system and kit comes with four External I/O Boxes and D-type 15-

pin connector cables enabling you to connect sensor inputs and relay

outputs. The pin signals and specifications for the external I/O Box and

the D-type 15-pin connectors are described below.

D-type 15-pin Connector Cable

External I/O Box

IN 1

IN 2

IN 3

IN 4

Video Card

External I/O Box

Relay Outputs 3

Sensor Input 3

Relay Output 2

Sensor Input 2

Sensor Input 1

Relay Output 1

D-type 15-pin connector

Sensor Input 4

AVerMedia LX5000 User’s Manual

14

Sensor Input Specification

Relay Output Specification

Surge strength: 1500 VAC

Nominal power: 200mw ~ 360mw

Operating power: 110mw ~ 200mw

COIL RATINGS (at 20

o

C )

Coil Nominal

Voltage

(VDC)

Coil

Resistance

(

10% )

Pick-up

Voltage

(VDC)

Drop-Out

Voltage

(VDC)

Nominal

Current

(mA)

5

125

3.75

0.5

40

* Max Continuous Voltage at 20

o