beautypg.com

C 9.92, Operating instructions, Maintenance after the first 500 service hours – Holder C 9.92 H User Manual

Page 184

background image

C 9.92

Operating Instructions

182

153 146

Maintenance after the first 500 service hours

-

Refit the drain plug with a new sealing ring. Make sure
that the plug is tight.

-

Fill recommended hydraulic oil through the filler neck (2).

Filling quantity .......................................... approx. 45 L

-

Check the oil level at the sight glass (3).

-

Refit the filler neck cap.

-

Start the engine. Operate the working hydraulic and
steering systems.

NOTE
The hydraulic system is vented automatically.

-

Shut off the engine and depressurize the hydraulic
system.

-

Check for leaks.

-

Check the oil level at the sight glass (3). Add hydrau-
lic oil if necessary.

Checking the engine valve clearances

-

See page 203 of maintenance every 1000 service
hours.

Bild_C992H_059

2

Bild_C992H_060

3