Henny Penny OFG-391 User Manual
Page 34

Model OFG- 391
2-16. CLEANING THE
Clean the dilution box monthly to ensure the unit operates
DILUTION BOX
efficiently and without failures.
1. Make sure unit is off, and close and lock the lid.
Lid should be in locked down position. Failure to do so
could result in personal injury.
2. Unscrew the wingnut on the lower left back access panel
of the fryer and remove the access panel. Clean the dilution
box with a cloth or brush. Make sure the holes in the box
are free of debris. Replace the back access panel when
finished.
Depending on the breading location and conditions within the
kitchen area, the dilution box may need cleaned more often.
2-17. CLEANING THE
The blower wheel must be cleaned annually to ensure the unit
BLOWER WHEEL
operates efficiently and without failures.
1. Make sure unit is off, and raise the lid.
Lid should be in locked down position. Failure to do so
could result in personal injury.
2. Remove the back shroud of the unit.
3. Remove the hose from the blower housing.
The blower tube will slide out of the bracket, instead of bolted,
on the newer fryers. See photo at left.
Depending on the breading location and conditions within the
kitchen area, cleaning the blower wheel, may need to be done
more frequently.
4. Clean the fins of the blower wheel, using a brush, or straight
blade screwdriver. Make sure the fins are clean of any debris.
2-17
305
Dilution Box