Model OFG- 391
Problem
Cause
Correction
HEATING OF SHORTENING SECTION
• Gas valve knob turned to the OFF
• Make sure the gas valve knob is
position
turned to the ON position.
• Blown fuse or tripped
• Reset breaker or replace fuse
circuit breaker at supply
box or control panel
• Blown fuse in PC board
• Replace glass fuse in board
•
Faulty POWER/PUMP switch
•
Check COOK/PUMP switch
per COOK/PUMP Switch Section
•
Faulty cord and plug
•
Check cord and plug and
power at wall receptacle
•
Faulty drain switch
•
Check drain switch per
Drain Switch Section
•
Faulty PC board
•
Remove and replace control
panel
•
Faulty high limit control switch
•
Check high limit control
switch per High Temperature Limit
Section
•
Drain valve open
•
Close drain valve
•
Possible faulty gas control
•
With power removed from
valve
fryer, check across electrical
leads of gas valve
with multimeter, and gas
valve on ON position
•
Possible faulty temperature probe
•
Replace temperature probe
•
Bad spark ignitor
•
Replace spark ignitor
•
Low air pressure
•
Clean or replace blower
•
Replace air pressure switch
•
Faulty ignitor module
•
Replace ignitor module
• Spark ignitor or flame sensor out of
• The spark ignitor needs to be 1/8 in.
adjustment
from the pilot hood, and the
flame sensor, 1/4 in
Shortening will not heat
305
1-7