Model OFG- 391
2-14. DRAIN VALVE
The drain valve opens when the drain valve handle is pulled out
AND EXTENSION
and drains the shortening out of the pot.
Replacement
1. Using a 3/8” socket, remove the nuts securing the drain switch
bracket, and pull the bracket from the studs.
2. Remove the nut securing the drain handle and pull the handle
from the drain valve.
3. Using a large adjustable wrench, unscrew the drain valve and
extension from the unit.
4. Replace the drain valve and extension.
5. Replace the drain switch bracket.
6. Adjust the microswitch to be no more than 1/8” (3 mm) from
the shaft of the drain valve.
NOTE: Listen for click of switch while pulling drain
valve handle.
2-15
305
See also other documents in the category Henny Penny Fryers:
- 590 (25 pages)
- OEA/OGA-342 (1 page)
- COMPUTRON 8000 (1 page)
- OEA/OGA-321 (78 pages)
- OFG-390 (2 pages)
- OEA/OGA-322 (1 page)
- none (12 pages)
- OFE-321 (46 pages)
- CLIMAPLUS LCS (84 pages)
- PFE-590 (80 pages)
- OFG-322 (1 page)
- OEA/OGA-324 (1 page)
- 690 (3 pages)
- 322 (11 pages)
- OFG-342 (2 pages)
- EVOLUTION ELITE EEG-144 (72 pages)
- 691 (1 page)
- OFE/OFG-323 (2 pages)
- FS-100 (2 pages)
- 680 (2 pages)
- PFE- 590/592 (3 pages)
- FS-200 (9 pages)
- 290 (17 pages)
- OEA-322 (2 pages)
- FDS-100 (2 pages)
- PFG-600 Gas (2 pages)
- OFE-341 (8 pages)
- 291 (20 pages)
- OFE-322 (2 pages)
- 342 (30 pages)
- OFE/OFG-324 (29 pages)
- ODG-323 gas (2 pages)
- OFE/OFG/OEA/OGA-341 (1 page)
- 500 (31 pages)
- EEE-144 (63 pages)
- FM03-681 (12 pages)
- G L O S S A R Y OFE- 290 (5 pages)
- PRESSURE FRYERS 600 (66 pages)
- 803 (1 page)
- OEA (22 pages)
- OFE-323 (2 pages)
- OFG-321 gas (2 pages)
- 341 (3 pages)
- FM07-020-F (40 pages)