Model OFG- 391
Problem
Cause
Correction
HEATING OF SHORTENING SECTION (Continued)
Heating of
•
Supply line too small - low
•
Increase supply line size
shortening too
gas volume
Refer to Installation
slow
Instructions Section of
Operator’s Manual
•
Improper ventilation
•
Refer to Installation
system
Instructions Section of
Operator’s Manual
•
Observe burners
•
Check gas pressure.
•
Improper air flow to burners
•
Check blower for resriction of
airflow
Shortening
•
Programming wrong
•
Check temperature setting
overheating
in the Program Mode
•
Faulty PC board
•
Remove and replace control
panel
•
Faulty temperature probe
•
Remove and replace
temperature probe
1-8
305
See also other documents in the category Henny Penny Fryers:
- 590 (25 pages)
- OEA/OGA-342 (1 page)
- COMPUTRON 8000 (1 page)
- OEA/OGA-321 (78 pages)
- OFG-390 (2 pages)
- OEA/OGA-322 (1 page)
- none (12 pages)
- OFE-321 (46 pages)
- CLIMAPLUS LCS (84 pages)
- PFE-590 (80 pages)
- OFG-322 (1 page)
- OEA/OGA-324 (1 page)
- 690 (3 pages)
- 322 (11 pages)
- OFG-342 (2 pages)
- EVOLUTION ELITE EEG-144 (72 pages)
- 691 (1 page)
- OFE/OFG-323 (2 pages)
- FS-100 (2 pages)
- 680 (2 pages)
- PFE- 590/592 (3 pages)
- FS-200 (9 pages)
- 290 (17 pages)
- OEA-322 (2 pages)
- FDS-100 (2 pages)
- PFG-600 Gas (2 pages)
- OFE-341 (8 pages)
- 291 (20 pages)
- OFE-322 (2 pages)
- 342 (30 pages)
- OFE/OFG-324 (29 pages)
- ODG-323 gas (2 pages)
- OFE/OFG/OEA/OGA-341 (1 page)
- 500 (31 pages)
- EEE-144 (63 pages)
- FM03-681 (12 pages)
- G L O S S A R Y OFE- 290 (5 pages)
- PRESSURE FRYERS 600 (66 pages)
- 803 (1 page)
- OEA (22 pages)
- OFE-323 (2 pages)
- OFG-321 gas (2 pages)
- 341 (3 pages)
- FM07-020-F (40 pages)