Honeywell RAPID EYE K9696V2 User Manual
Page 63

Other Site Hardware
5–5
Honeywell recommends that cable not be “T-tapped”; this can introduce
unwanted distortion into the video signal.
To obtain a video feed, use an output port on the Multi video unit.
5.4.3 Configuring
PTZ
You can use other PTZ hardware and its software driver at another site. For software
driver and baud rate, see table 13.
Configure each PTZ unit to communicate at its default baud rate. See the Rapid Eye
Multi-Media Admin User Guide for procedures to enable a PTZ dome.
Table 13
PTZ drivers for controllers and domes
Driver name
(alphabetical )
Baud rate
Supported controller/dome
Javelin 308
9600
Javelin 308 Controller and others
Kalatel
9600 or 2400
Kalatel KTD 312 Cyberdome
Pelco D
4800*, 9600, or 2400
Pelco D: many domes
Pelco P
2400
Pelco P: many domes
Rapid Dome/Orbiter
†
9600
RapidDome or Orbiter
Sensormatic RS422
§
4800
SensorMatic RS422: Delta and Speed
Ultrak (using VCL)
2400
Ultrak (configured as VCL)
* A value of “4800” is typical; other values can be used as needed.
†
In other versions, this driver is jav306 or Javelin/ADEMCO.
§
This driver’s name was “Delta” in older versions of View.
After selecting a driver for PTZ, adjust the domes post-use behavior by using View
software and running a Maintenance session. The settings are on the Video tab.
Fig. 44. Video tab: PTZ settings.