Codabar, Codabar start / stop characters, Codabar check character – Hand Held Products 2020 User Manual
Page 93: Codabar -3, Codabar start/stop characters, Default all codabar settings
![background image](/manuals/88816/93/background.png)
6 - 3
Codabar
Codabar
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit
.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the image scanner to read only Codabar barcodes with Modulo 16
check characters.
Default = No Check Character.
No Check Character
indicates that the image scanner reads and transmits
barcode data with or without a check character.
When Check Character is set to
Validate and Transmit
, the image scanner will
only read Codabar barcodes printed with a check character, and will transmit this
character at the end of the scanned data.
* On
Off
Transmit
* Don’t Transmit