Troubleshooting Checklist
4-8 Troubleshooting
Troubleshooting Checklist
If the module is not working properly, refer to
on page 4‐8 for a checklist of
problems, possible causes, and recommended actions to resolve the problem.
Table 4-2 Troubleshooting Checklist
Problem
Possible Cause
Recommended Action
All LEDs are OFF.
Loss of power.
Ensure that the DFE module was installed
properly according to the installation
instructions in
, and that the
host chassis is providing power.
No Local
Management
Password screen.
Incorrect terminal setup.
Refer to the Enterasys Matrix DFE-Gold
Series Configuration Guide for proper
setup procedures.
Improper console cable
pinouts.
for proper COM port
pinouts.
Corrupt firmware image, or
hardware fault.
If possible, attempt to download the
image to the DFE module again. Refer to
“
for instructions to clear NVRAM.
Cannot navigate
beyond Password
screen.
Improper username/ password
combination entered.
If the username/password combination
has been forgotten, refer to “
instructions on how to set the mode
switch to reset the username/password
combination to the default values.